CTG2000ANG/CTG3000ANG/CTG5000ANG 2 Rev. 03/15/17
SPECIFICATIONS
Notes from Page 1:
*1: The accuracy of the readout is guaranteed from
20% to 100% of maximum range + /- 1 increment.
The torque accuracy is a typical value. Calibration
point is at the middle line of the five anti-slip
lines on the rubber handle. To maintain the
accuracy of the torque wrench, calibration should
be performed once a year or every 5,000 cycles,
whichever comes first. Accuracy is based on the
zero degree of offset from perpendicular drive.
*2 The angle accuracy is guaranteed at ±2%
clockwise, ±3% counterclockwise when rotating
wrench to 90º at the speed of 30º/s.
*3: Uses two AA batteries and has auto shut-off
feature when idle for approximately 2 minutes.
FAILURE TO OBSERVE THESE WARNINGS COULD RESULT IN INJURY
WARNING - FOLLOW THESE RULES FOR SAFE OPERATION!
THIS INSTRUCTION MANUAL CONTAINS
IMPORTANT SAFETY INFORMATION.
READ THIS INSTRUCTION MANUAL CAREFULLY
AND UNDERSTAND ALL INFORMATION BEFORE
OPERATING THIS TOOL.
It is the responsibility of the owner to make sure all
personnel read this manual prior to using the device.
It is also the responsibility of the device owner to
keep this manual intact and in a convenient location
for all to see and read. If the manual or product
labels are lost or not legible, contact Cornwell Tools
for replacements. If the operator is not fluent in
English, the product and safety instructions shall be
read and discussed with the operator in the
operator's native language by the purchaser/owner
or his designee, making sure that the operator
comprehends its contents.
• To safeguard torque accuracy avoid keeping tool
set at high loads for long periods of time. When
finished reset back to zero.
• Do not operate without eye and hand
protection (users and bystander).
• Keep body working stance balanced and firm.
Do not overreach when operating the tool.
• Keep fingers and hands away from pinch
point region of this tool at all times.
• Do not force tool beyond its rated capacity.
Overtorqueing can cause breakage.
• Use of a "cheater bar" or leverage multipliers will
result in an inaccurate reading and can possibly
damage the wrench. Use of unapproved
accessories could push the unit beyond its rated
capacity and will void your warranty.
• Do not use torque wrench to loosen fasteners.
• The wrench should be sent in for calibration once
every year or every 5,000 cycles for re-calibration.
• The wrench should be cleaned and stored
properly after every use.
Do not submerge this unit
in any fluid.
• Wrenches should be re-calibrated if dropped or
accidentally mishandled.
• The torque wrench should be "exercised" a
minimum of three times at 100% of full scale
before use.
• Do not remove any labels. Replace damaged
labels.
• Communications port is for use by authorized
service center technicians only.
• This product may contain one or more chemicals known
to the State of California to cause cancer and birth
defects or other reproductive harm. Wash hands
thoroughly after handling.
• Failure to heed these warnings may result in
serious or fatal personal injury and/or
property damage.