Alarms
If the machine detects an error, this information is presented in a pop-up screen and for as long as
one or more problems exist, there is a warning symbol in the top right corner of the default view.
The alarms that can be displayed are the following, each presented with recommendation on what to
do.
One or more slaves are not
responding
This alarm is presented when the machine, used
as Master on a network, has lost connection with
one or more of its slave machines. If it is
presented, check all the system cables and the
power to the respective machines. As soon as
communication is re-established, the alarm will
automatically disappear.
Ambient temperature too high!
The machine has shut off all heaters due to too
high ambient temperature, above 40 degrees
Centigrade. If continuous fan is selected, the fan
will continue operating. The machine
automatically resumes operation if the
temperature drops.
The fan speed deviates from what is expected. If
this remains, please contact service technician.
Mainboard connection failure
Internal error. If it remains, please contact service
technician.
Internal RHT sensor failure
Internal error. If it appears after the machine has
been disassembled it might be so that the sensor
connector to the lid has not been correctly
mounted. If not and if it remains, please contact
service technician.
External RHT sensor failure
The machine has lost contact with the external
RHT sensor(s). Please check that the cables are
correctly mounted. When loosing the external
sensors, the machine automatically reverts to
using the built-in RHT sensor.
Failed to save the statistics
Internal error. If it remains, please contact service
Setpoint RH 60%, start drying.