Immediately after the capacity mode name,
there is a symbol, either ↕, ↑ or ↓. The first
symbol, the ↕, indicates that the wet air
volume is correct, in balance. The down
arrow, ↓, means that the wet air volume
should be decreased and the up arrow
means that it should be increased. If the wet
air volume is incorrect, use right arrow
button to proceed to the capacity mode
menu and use the wet air meter as guidance
while adjusting the wet air throttle.
The rotor is rotating
anti-clockwise as
seen through the dry
air outlet or doesn’t
rotate at all.
Rotor motor or the motor
capacitor is faulty.
Contact your retailer for repair.
No air is blowing, the
fan is not running.
The machine has been set in
standby.
The dehumidifier is set to a
control mode other than
MAN, manual, continuous
fan function is off and the
ambient humidity is so low
that the machine is now in
standby.
The machine is operating on
timer and currently in stand-
by.
Push either Start to start the machine with
default settings or Resume to start with the
previous settings.
Check the control mode in the lower left
corner of the machine For continuous
operation, it should read MAN as in manual
mode. If other mode is used, check the
setpoint.
For continuous fan, use right arrow button to
step to the Fan mode menu and activate
Continuous fan.
If applicable, adjust the set point of the
humidistat.