CEMP ENERGY METERING DATA
NOTE: The below data, temperatures and current levels etc., relate to the built-in energy metering
function, the CEMP, alone and not to the complete machine.
The CEMP declaration of conformity is available at www.corroventa.com/mid-certificate/.
Accuracy class
Class B
Rated Operating conditions
Voltage
230VAC
Frequency
50Hz
Power factor
0.5ind. to 0.8cap.
Current
I st
0.02A
I min
0.25A
I tr
0.5A
I ref
5A
I max
45A
Operating temperature
-25°C to + 55°C
Climate
Non-condensing
Environment/position
Closed location
Electromagnetic environment class
E2
Mechanical environment class
M2
Max capacity of energy register
9 999 999,9 kWh
Notified body
0402