41
LP/PROPANE GAS CONVERSION
IMPORTANT: Gas conversions must be done by a qualified service technician
in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. The qualified agency
performing this work assumes the gas conversion responsibility.
Convert Gas Pressure Regulator
Regulator Cap
Retainer Pin
Natural gas
position
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
3. Locate the gas pressure regulator on the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
4. Unscrew the regulator cap with the wrench.
5. Remove the retainer pin that is currently positioned for use with natural
gas.