INSTALLATION MANUAL
Submersible Two-Stage Grinder Pump
IMPORTANT! Read all instructions in this manual before operating pump.
As a result of Crane Pumps & Systems, Inc., constant product improvement program,
product changes may occur. As such Crane Pumps & Systems reserves the right to
changeproductwithoutpriorwrittennotication.
420 Third Street 83 West Drive, Bramton
Piqua, Ohio 45356 Ontario, Canada L6T 2J6
Phone: (937) 778-8947 Phone: (905) 457-6223
Fax: (937) 773-7157 Fax: (905) 457-2650
www.cranepumps.com
Form No. 145629-Rev. A
Series: ZOGP
This product may be covered by one or more of the following patents and other patent(s) pending: Patent Pending

Questions and Answers

  • M
    Matthew YoungAug 4, 2025
    How to fix a Crane Water Pump that will not run?
    • A
      Ashley RodriguezAug 5, 2025
      If your Crane Water Pump isn't running, start by checking all electrical connections to ensure they are secure. Also, inspect the fuse and breaker to see if they've blown or tripped, indicating a power interruption. If the connections are faulty, fix them.
  • T
    Tanya LeeAug 10, 2025
    Why won't my Crane Water Pump turn off?
    • S
      smithdonnaAug 11, 2025
      Your Crane Water Pump might not be turning off due to several reasons: * Float movement might be restricted. * The switch may not be activating the pump or could be defective. * There might be excessive inflow, or the pump isn't properly sized for the application. * The pump could be airlocked. * The H-O-A switch on the panel might be in the “HAND” position.
  • L
    Lisa ThompsonAug 17, 2025
    Why does my Crane BARNES RAZOR ZOGP Water Pump hum but not run?
    • A
      Andrew MartinAug 17, 2025
      A Crane Water Pump humming but not running could be due to incorrect voltage or a cutter that is jammed or loose on the shaft, worn or damaged, or an inlet that is plugged.
  • L
    Lorraine OrtizAug 23, 2025
    Why is my Crane Water Pump cycling too frequently?
    • J
      juliemillerAug 23, 2025
      If your Crane Water Pump cycles too frequently or runs periodically when fixtures aren't in use, this could be due to a check valve stuck closed or installed backward, leaking fixtures, or ground water entering the basin.
  • A
    Ann FernandezAug 28, 2025
    Why does my Crane Water Pump shut off and turn on by itself?
    • L
      Laura LewisAug 28, 2025
      If a Crane Water Pump shuts off and turns on independent of the switch, tripping the thermal overload protector, it could be due to incorrect voltage, excessive inflow, the pump not being properly sized for the application, a jammed cutter, or excessive water temperature.

Summary

Safety First

Safety Symbols and Warnings

Explains hazard symbols and critical warnings.

General Safety Precautions

Covers electrical, handling, and operational safety guidelines.

Material and Environmental Safety

Addresses handling of returned products and material content.

User Guide

Pump Usage and Care

Guidelines for operating the pump and what not to pump.

Power Failure and Warranty Registration

Procedures for power outages and warranty activation.

Pump Specifications

Technical Specifications

Lists discharge, materials, bearings, motor, and cord details.

Pump Dimensions

Visual representation and measurements of the pump.

Pump Diagrams

CT and L Model Diagrams

Visual representation and measurements for specific pump models.

Model Data and Electrical Requirements

Model Number and Electrical Specifications

Table detailing pump models, HP, voltage, amps, etc.

Recommended Breaker Sizes and Nameplate

Guidance on circuit breakers and identifying pump information.

Installation and Connections

Receiving, Storage, and Installation Procedures

Steps for handling, storing, and installing the pump.

Electrical Connections and Cable Handling

Guidance on wiring, connections, and cable management.

Cable Connections

Power and Control Cable Connections

Details on connecting power and control cables, and wire sizing.

Wiring Diagrams (Phase Power)

Single and Three Phase Power Wiring

Diagrams for various AC power configurations.

Wiring Diagrams (Control;Panel)

Control Panel and Series Wiring

Diagrams for control panels and specific series wiring.

Generic and Panel Wiring

Typical Generic Wiring Diagram

Illustrates a general setup with pump and alarm panel.

Upgrade Core Panel Wiring

Shows wiring for specific panels.

Station Wiring

EONE 200 Series Package Wiring

Wiring instructions for EONE 200 series packages.

2000 Series Station Wiring

Wiring instructions for 2000 series stations with EQD.

Troubleshooting

Common Pump Problems and Solutions

A guide to diagnosing and fixing operational issues.

Parts List

Pump Component Identification

Lists parts with part numbers and descriptions.

Parts Kits

C-Channel and BSP;NPT Discharge Kits

Details on available kit configurations.

Warranty Information

Limited 3 Year Warranty Terms

Details the warranty coverage and limitations.

Warranty Registration and Returns

Warranty Registration and Returned Goods Policy

Instructions for warranty activation and product returns.

Start-Up Report

General Information and Pre-Startup Checks

Fields for pump details and initial checks.

Operational Checks and Follow-up

Operational Checks and Corrective Actions

Post-installation tests and follow-up requirements.

Crane BARNES RAZOR ZOGP Series Specifications

General IconGeneral
BrandCrane
ModelBARNES RAZOR ZOGP Series
CategoryWater Pump
LanguageEnglish

Related product manuals