Original instructions.
To activate these functions, turn o the machine at the power switch then, while holding down the
required button on the left-side drinks button bank, turn the machine back on.
Short Espresso (K1): Enable / Disable electronic pre-infusion.
Medium Esp. (K2): Enable / Disable automatic hot water function on Continuous button.
Long Espresso (K3): Start auto-cleaning.
Group Flush (K4): Turn on/o ashing of button lights.
· Additional button functions
· Programming the coee dosage
i
This section explains how to program the doses dispensed automatically by the drink buttons.
Note:
Programming any of the options on the left-hand Drink buttons (when viewing the machine
from the front) automatically sets the dispensing volumes on all of the other Drink buttons.
This only applies to the left-hand Drink buttons. Programming other Drink buttons only
modies the option selected.
Group ush button (K4) can be programmed as an standard drink if desired.
Important:
Use a portalter lled with fresh coee for every new dose you program.
On machines not equipped with a display, hold down the Continuous Dispensing (K5) button
for 8 seconds. The Continuous Dispensing (K5) button light will ash.
Press the dispensing option that you wish to program: Short Espresso (K1), Medium Espresso (K2)
and Long Espresso (K3). The light on the button pressed and on the Continuous Dispensing button
will remain on.
The group will start dispensing coee. When the desired volume is reached in the cup, press the
selected button again to stop dispensing. This volume setting will be saved.
Repeat this process for all of the dispensing options that you wish to reprogram.
If you only need to reprogram one of the dispensing options, follow the steps above and program just
that option. All of the other dispensing options will remain unchanged (default settings).