EasyManua.ls Logo

Crem EX2 - User Programming - Display PID Versions; Programming Coffee;Tea Dosage; User Menu - Access & Browsing

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Original instructions.
· Programming the coee / tea dosage
This section explains how to program the doses dispensed automatically by the drink buttons.
· User menu – Access & browsing
To access the user programming settings, follow the steps below:
1. Hold down K5 for 8 seconds, until [SEL] message is shown on the display and K5 ashes.
(Programming dosages)
2. Hold down K5 for 8 seconds again, until [t0] (1
st
menu setting) is shown on the display.
3. Browse through the menu by pressing K1 & K2.
4. Access to each setting by pressing K5. The adjustable parameter will ash. Accept and save by
pressing K5 again.
5. To exit from the menu, browse to [ESc] (Escape) and press K5.
· User menu – Settings summary chart
Important:
Use a portalter lled with fresh coee for every new dose you program.
On machines equipped with a display:
1. Hold down K5 for 8 seconds, until [SEL] message is shown on the display and K5 ashes.
2. Press the dispensing option that you wish to program: Short Espresso (K1), Medium Espresso
(K2), Long Espresso (K3) and Flush (K4). The light on the button pressed and K5 button will
remain on. The group will start dispensing coee.
3. When the desired volume is reached in the cup, press the selected button again to stop
dispensing. This volume setting will be saved.
Repeat this process for all the dispensing options that you wish to reprogram.
If you only need to reprogram one of the dispensing options, follow the steps above and program just
that option. All the other dispensing options will remain unchanged (default settings).
To come back to home screen, wait 30 seconds or turn the machine o and on again.
i
Note:
Programming any of the options on the left-hand Drink buttons (when viewing the
machine from the front) automatically sets the dispensing volumes on all of the other
Drink buttons. This only applies to the left-hand Drink buttons. Programming other
Drink buttons only modies the option selected.
Group ush button (K4) can be programmed as an standard drink if desired.
If K5 is enabled as Tea button, the automatic hot water dosage can be programmed by
time on K5. This dosage will be independent on each group.
Setting Description
[t0]
Boiler temperature
[cro]
Chrono setting (shot timer)
[Pi X]
1
Preinfusion (Gr1, Gr2 & Gr3)
SSP
2
SmartSteam Pump
SSo
2
SmartSteam Air oset
SSt
2
SmartSteam temperature
[Eco]
1
Eco mode timer
[Std]
1
Eco mode stand-by timer
Setting Description
[SEc]
Eco mode boiler temperature
[SLc]
Service liter counter (water lter)
[Scc]
Service coee counter (maintenance)
[tot]
Total counters
[cLo]
Clock settings
[AUt]
1
Auto on/o function
1
Disabled by default on service menu
2
Only SmartSteam models
USER PROGRAMMING - DISPLAY PID VERSIONS

Related product manuals