EasyManuals Logo

Crestron DM-RMC-SCALER-C User Manual

Crestron DM-RMC-SCALER-C
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Crestron DM-RMC-SCALER-C DigitalMedia 8G+ Receiver
Operations & Installation Guide DOC. 7231B DigitalMedia 8G+ Receiver: DM-RMC-SCALER-C
19
Uploading and Upgrading
Crestron recommends using the latest programming software and that each device
contains the latest firmware to take advantage of the most recently released features.
However, before attempting to upload or upgrade it is necessary to establish
communication. Once communication has been established, files (for example,
firmware) can be transferred to the device. In addition, the IP table of the device can
be configured.
NOTE: Crestron software and any files on the website are for authorized Crestron
dealers and Crestron Service Providers (CSPs) only. New users must register to
obtain access to certain areas of the site (including the FTP site).
Establishing Communication
Use Crestron Toolbox for communicating with the DM-RMC-SCALER-C; refer to
the Crestron Toolbox help file for details.
A PC running Crestron Toolbox communicates with the DM-RMC-SCALER-C in
the following ways:
Via a DM switcher using TCP/IP or USB communication. TCP/IP provides
a faster method of communication than USB.
Via the LAN port of the DM-RMC-SCALER-C using TCP/IP
communication. In this scenario, the DM-RMC-SCALER-C is used in a
standalone configuration (a DM switcher is not used).
Via DM Switcher
TCP/IP Communication via DM Switcher
DM SWITCHER
PC Running
Crestron Toolbox
DM 8G+
LAN
24 V
0.75
A
MAX
PWR
DM
LIN K
VIDEO
USB HID
SETUP
RESET
DM-RMC-SCALE R-C
DM ROOM CONTROLLER
HDMI OUT
USB HID
COM
IR
1 2
S G S G
GND
TX
RX
RTS
CTS
DM-RMC-SCALER C
To establish TCP/IP communication between the PC and the DM-RMC-SCALER-C
via the DM switcher:
1. Establish communication between the PC and the DM switcher as described
in the DigitalMedia Switchers Operations Guide (Doc. 6755).
2. Use the Device Discovery Tool in Crestron Toolbox to find the IP address
of the DM-RMC-SCALER-C. The tool is available in Toolbox version
1.15.143 or later.
3. Use the Address Book in Crestron Toolbox to create an entry for the
DM-RMC-SCALER-C using the TCP connection type, and enter the IP
address of the DM-RMC-SCALER-C.
4. Display the DM-RMC-SCALER-C’s “System Info” window
(Tools | System Info); communications are confirmed when the device
information is displayed.

Other manuals for Crestron DM-RMC-SCALER-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crestron DM-RMC-SCALER-C and is the answer not in the manual?

Crestron DM-RMC-SCALER-C Specifications

General IconGeneral
Product colorBlack
Heat dissipation41 BTU/h
Housing materialMetal
Scaled resolutions640 x 480, 800 x 600, 848 x 480, 1024 x 768, 1280 x 1024, 1280 x 720, 1280 x 768, 1280 x 800, 1360 x 768, 1366 x 768, 1400 x 1050, 1440 x 900, 1600 x 1200, 1600 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200
RJ-45 ports quantity1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 90 %
AC adapter frequency50/60 Hz
AC adapter input current0.75 A
AC adapter input voltage100-240 V
Weight and Dimensions IconWeight and Dimensions
Depth37 mm
Width194 mm
Weight870 g