Safety information:
Read and understand all instructions in the opera-
tion section of this manual before use.
Do not substitute components as this may impair
intrinsic safety and invalidate warranty.
Observe all warnings and instructions marked on
the unit and within this manual.
Observe site health and safety procedures for
gases being monitored and evacuation proce-
dures.
Make sure you understand the screen display and
alarm warnings.
If this product is not working properly, read the
troubleshooting guide or call Crowcon.
Ensure qualified service personnel change sensors
and operating system.
Ensure maintenance and calibration are carried
out in accordance with the procedures in the man-
ual.
Instructions specific for use in hazardous areas
The following instructions apply to equipment cov-
ered by certificate numbers:
Tetra 3 = Baseefa 05ATEX0187
Tetra 3 = IECEx BAS 05.0059
The following information covers all relevant points list-
ed in clause 1.0.6 of the EHSR’s of the ATEX directive.
1. The certification marking is as follows:
2. The equipment may be used in zones 1 and 2 with
group IIA, IIB, and IIC flammable gases, tempera-
ture classes and vapours T1, T2, T3 and T4.
3. The equipment is certified for use in ambient tem-
peratures in the range –20°C to +55°C
(-4 to +131 F). The equipment should not be used
outside these ranges.
4. Compliance with the Essential Health and Safety
Requirements has been assured by compliance with
IEC 60079-0, 60079-1,60079-11, EN61779-5, as
certified by Baseefa. Compliance with gas detec-
tion performance standards EN50054, EN50057,
EN61779-1, EN61779-4 and EN50104 and
EN50270 has been certified by Lloyds Register.
5. Repair of this equipment and gas sensor replace-
ment shall be carried out by the manufacturer or
in accordance with the applicable code of prac-
tice.
6. If the equipment is likely to come into contact
with aggressive substances, then it is the responsi-
bility of the user to take suitable precautions that
prevent it from being adversely affected, thus
ensuring that the type of protection is not com-
promised.
7. The rechargeable battery must only be charged in
non-hazardous (safe) areas by connection to the
specified Crowcon charger power supply.
8. The equipment is not certified for use in atmos-
pheres containing more than 21% oxygen.
Area Classifications: -
Zone 1: An area classified as Zone 1 is likely to have
ignitable concentrations of flammable gases,
vapours or liquids present under normal oper-
ating conditions.
Zone 2: An area classified as Zone 2 is not likely to
have ignitable concentrations of flammable
gases, vapours or liquids present under nor-
mal operating conditions.
© Copyright Crowcon Detection Instruments Ltd 2007.
All rights are reserved. No part of the document may be pho-
tocopied, reproduced, or translated to another language with-
out the prior written consent of Crowcon Detection
Instruments Ltd.
Publication number: M07654
Fourth edition: December 2007
Crowcon Detection Instruments Ltd
2 Blacklands Way, Abingdon
OX14 1DY UK
Tel. +44 (0)1235 557700
Fax. +44 (0)1235 557749
www.crowcon.com
Email: sales@crowcon.com
EEx ia d IIC T4
OX14 1DY
UNITED KINGDOM
II 2G
1180
4F/20 ºC Ta 131F/55 Cº
4F/20 C Ta 131F/55 Cºº
IEC Ex ia d IIC T4
BASEEFA05ATEX0187
IECEx BAS 05.0059
FOR INTRINSIC SAFETY PRECAUTIONS SEE
MANUAL. WARNING UNDERSTAND MANUAL
BEFORE OPERATING. ONLY CHARGE BATTERY
IN A NON HAZARDOUS AREA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crowcon Tetra 3 and is the answer not in the manual?

Crowcon Tetra 3 Specifications

General IconGeneral
BrandCrowcon
ModelTetra 3
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals