EasyManua.ls Logo

Crown Xavier X-4KW-M - Function Setting: Output Source Priority Timers; Timer Settings for Output Source Priority

Crown Xavier X-4KW-M
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Error message for USB On-the-Go functions:
Error Code Messages
No USB disk is detected.
USB disk is protected from copy.
Document inside the USB disk with wrong format.
If any error occurs, error code will only show 3 seconds. After three seconds, it will automatically return to
display screen.
2. Timer Setting for Output Source Priority
This timer setting is to set up the output source priority per day.
Procedure LCD
Screen
Step 1: Press and hold “ ” button for 3 seconds to enter Function Setting Mode
for output source priority.
Step 2: Press “ ”, ” or “ ” button to enter the selectable setting
programs (detail descriptions in Step 3).
Step 3: Please select setting program by following each procedure.
Progra
m#
Operation Procedure
LCD
Screen
Press “
” button to set up Utility First Timer. Press “ ” button to
select staring time. Press “
” button to adjust values and press
” to confirm. Press “ ” button again to select end time. Press
” button to adjust values, press “ ” button to confirm. The
setting values are from 00 to 23, with 1-hour increment.
Press “
” button to set up Solar First Timer. Press “ ” button to
select staring time. Press “
” button to adjust values and press
” to confirm. Press “ ” button to select end time. Press
” button to adjust values and press “ ” button to confirm. The
setting values are from 00 to 23, with 1-hour increment.