CDR-3250/80 TECHNICAL MANUAL
Issue 2.2 3-39
Utility - CONFIG - REMOTE - NEXT Soft Key Menu.
SHARE IDENT DONE
MTR
MNU
NEXT
Press the IDENT key to send the identification message out over the bus. The message identifies the manufacturer, the
equipment name, the firmware version number, and date, and copyright notice. This message is less than 125 characters long.
3-7.5.2.2.2 IEEE-488 Bus.
(If so equipped). To configure the receiver IEEE-488 bus remote control operation, select the
Utility - CONFIG soft key menu as shown below.
Utility - CONFIG Soft Key Menu.
INIT REMOTE PWRDWN ROLOFF CANCEL
MTR
MNU
NEXT
Press REMOTE to change the remote control bus configuration. The following menu appears.
Utility - CONFIG - REMOTE Soft Key Menu.
ADDRS DONE
MTR
MNU
NEXT
Press ADDRS to select the receiver's bus address. The following menu appears.
Utility - CONFIG - REMOTE Soft Key Menu.
BKSP ENTER RETURN
MTR
MNU
NEXT
Enter the receiver's bus address using the keypad or knob (range = 000 - 030). Press ENTER when done.
3-7.5.2.3 Configuring Receiver Default Settings.
To configure the receiver's default settings select Utility - CONFIG soft
key menu as shown below.
Utility - CONFIG Soft Key Menu.
INIT REMOTE PWRDWN ROLOFF CANCEL
MTR
MNU
NEXT
Select PWRDWN to determine if the current receiver operating parameters will be saved or not when the receiver is turned off.
The following menu appears.