CDR-3250/80 TECHNICAL MANUAL
Table 3-5 Radio Command and Status Messages.
Syntax Reply Description
3-62 Issue 2.2
SS? SS±123
Request signal strength: The ± character represents the sign of the value
and will be either + or -. Digits 1 through 3 represent the significant digits
of the signal strength in dB relative to one milliwatt where:
1 represents 100 dB,
2 represents 10 dB, and
3 represents unit dB increments. (Range: -116 through +012).
ST###
STore current operating parameters into memory channel. ###
represents the three digits of the memory channel being stored to.
SW###
Begin SWeep of frequency bands. ### represents the three digits of the
highest odd numbered memory channel from which to take the sweep
stop frequency. The sweep starts at the frequency of the channel most
recently recalled with the RC### command. (Range: 0 through 249)
(cont)