CDR-3250/80 TECHNICAL MANUAL
Table 3-5 Radio Command and Status Messages.
Syntax Reply Description
Issue 2.2 3-67
Y123
Change receiver AGC decay time. Digits 1 through 3 represent the
significant digits of the AGC decay time in units of 10 ms. With the 1
representing the units of seconds digit, 2 the 100s of milliseconds, and
the 3 the 10s of milliseconds. Values must be taken from the following list:
0, 1, 2, 3, 4, 6, 8, 10, 20, 30, 40, 60, 80, 100, 200, 300, 400 and represent
decay times ranging from 0.00 to 4.00 seconds. For example, to set the
AGC decay time to 0.6 seconds, the command Y60 would be sent. The
AGC Decay setting has no effect in the AM and FM modes. Changes
made with this command are affected by the current ISB Access Mode.
Y?
Request current AGC Decay Time.
NOTES:
1
Status request commands marked with this note may not be mixed with any other status requests in a single
transmission.