26 Culligan® CSM Series Softeners
26 Cat. No. 01016370
Installation and Operation of the Blocking Solenoid Valve FOR Multi-Tank
Alternating Operation
NOTE Proceed to page 27 if your system is a single tank configuration.
The solenoid valve is only required for multiple unit alternating or
progressive flow systems.
The purpose of the solenoid valve is to assist the controller in providing automatic
alternation of multiple tank systems. Each Brunermatic multiport valve in the system will
require its own solenoid valve. These solenoids are tubed as follows:
From solenoid valve port number 1 to Brunermatic multiport valve port number 4.
From solenoid valve port number 2, tee into the tubing that attaches to the “IN”
port on the pilot valve body.
From solenoid valve port number 3 to port number 2 on the pilot valve body. The
detailed tubing schematic is shown below (Figure 37).
Wiring is detailed on page 34.
2
5
DR
3/4
6
P
1
Brunermatic
Valve
Figure 38. ALTERNATING/PROGRESSIVE FLOW PARALLEL SYSTEM W/PLUGGED BYPASS
Figure 37. Solenoid
Valve Kit