4
Tank Temperature Check
TurnonbreweratthecontrolpanelON/OFFbutton.Pressandhold3button(seeillustration,page2)for5seconds.WaterTemperaturewillbedisplayed.
Brew Volume – Easy Access–NotonUsedonModelTA-60
UnitsproducedbeginningJanuary2008canbeeasilyadjustedfromthefrontpanel.WrittenintothesoftwareontheD60GTUCM,isafeaturetoaccessthe
brew volume without entering the program mode.
TheUCMmustbeon.ToadjusttheD60GTmodel,pressandholddownthecenter,Selectbutton2.Thescreenwillread pressing<or
>willadjustthebrewvolumeupordown,±20oz,in1ounceincrements.
ADDITIONAL UCM FEATURES
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set.
Pulse Brew (Factory setting OFF)
Press to select, < or > to select OFF or one of four pulse patterns (A to E) .
Guidelines for Pulse Brew:
This feature allows tuning of the coffee avor. The pot level should always be set rst with this option OFF. Depending on your
grind prole and water conditions, the ve Pulse Brew options help “tune” or change the coffee avor. Filter Pack type coffees
typically extract better with the A and B pulse setting. Decaffeinated coffees typically extract better with the B pulse setting. High-
Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste
prole. There are two additional settings (D and E) that allow you to manually set the ON TIME pulses and OFF TIME.
If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock does not ap-
pear the list of program selections. When Pulse Brew is ON, Pre-infusion disappears from the list of program selections.
Display Brew Time (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When on, the Display Brew Time fea-
ture allows you to see the remaining time in the brewcyle counting down.
Drip-Out Mode (Factory set to 2 min)
Press to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF. Time counts up
in 5 second increments. Press to set.
Display Messages (Factory set to ON)
Press to turn ON or OFF. The message displayed is “Rinse Server Before Brewing”. This message will alternate; two seconds
with Rinse Server Before Brewing, then Curtis READY TO BREW will appear for six seconds.
Language (Factory set to English)
Pressing < or > toggles between English and French. Press to set.
Model Select
Press to select, < or > to select model. The selections are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer, Thermo-Alpha (for
the D60GT). Press to set. When the Model Select feature is changed, all settings are reset to the defaults of the newly selected
model.
Exit
Press to select, exits program mode and returns unit to operation.

Questions and Answers: