Curtis PMC 1204X/1205X/1209/1221 Manual
11
WIRING
WIRING
CONNECTIONS: Low Current
Two 1/4" push-on terminals are provided for the throttle inputs. If your
controller has a voltage throttle input, there will be only one throttle terminal.
A 6-pin low power connector molded into the right side of the controller
face provides the low power logic control connectionsKSI input, forward/
reverse contactor output, bypass contactor output (optional), emergency reverse
(optional), and forward and reverse inputs.
Several manufacturers make mating connectors that t this connector. The part
numbers listed are for the recommended 0.75 mm
2
(#18 AWG) vinyl insulated
stranded wire.
MFR PART NUMBER DESCRIPTION
AMP #640426-7 locking, insulation displacement terminals,
wires at right angle to connector
Methode #3300-107-218 locking, insulation displacement terminals
Molex #09-50-3071 locking, crimp terminals
Panduit #CE156F18-7 locking, insulation displacement terminals,
wires at right angle to connector
3
Throttle inputs
3
Keyswitch input (KSI)
F/R contactor output
Bypass contactor output
Emergency reverse input
Forward input
Reverse input
1
2