NO Function Detail of Data Initial factory
setting
MODBUS
Address
58 Motor rated frequency Fb 10~240HZ (Fb)
FH
Fb
60 186
59 Stagnancy of current
detected
2~10% 2 187
60 V/F Frequency FC 0.5~240HZ 20 188
61 P.W.M. Frequency 1 0: P.W.M. Frequency set by Cd62
1: 4KHZ
2: 5KHZ
3: 6KHZ
4: 7KHZ
5: 8KHZ
6: 9KHZ
7: 10KHZ
2 189
62 P.W.M. Frequency 2 15~160 30 190
63 Start frequency of auto
voltage compensation
3.0~20.0HZ 10 191
64 Dynamic braking mode 0~1 1 192
65 Instant initial field time 1~7 1 193
66 Digital filter function 1~6 5 194
67 Power source positioning
accuracy calibration
0~30 0 195
68 Motor vibration
compensation
100~500 200 196
69 Motor speed search time 0~15 15 197
70 Dynamic braking active level
120~140% 130 198
71 Over Voltage prevention
function active point
130~150% 140 199
79 Auto record when power off
0: unuse
1: use
1 207
80 Modbus protocol data frame
and Communications mode
setting
0 208
81 RS485 Communication ID
Setting
1~240 240 209
82 RS485 Baud rate
0
2400 bps
1
4800 bps
2
9600 bps
3
19200 bps
2 210
83 Series communication
response time.
5~15
5
211
90 Series communication
Parameter store eeprom
Cd90=0 unstore
Cd90=1 store one data and reset 0
0
218