Rear Roller
Tools Required:
• Phillips screwdriver
• Long 3/8” drive socket extension
• 3/4” Socket wrench
• 9/16” Socket wrench
Disconnect power source
1. Toggle the on/off (I/O) power switch to the off (O) position. The on/off (I/O) power switch is located
under the front end of the unit, or on the front right side panel.
2. Unplug the treadmill from the power outlet.
Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing
maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
Remove end caps
1. Remove two screws securing right end cap using a Phillips screwdriver.
Qty.DescriptionItem
2Screws1
1Right end cap2
2. Repeat step for left end cap.
Page 108 of 209
Cybex 625T Treadmill Part Number