SVC - Belt and Deck service odometer
The message SVC is displayed with no error codes listed.
Cause: The 625T Treadmill has a service odometer for the running belt and deck. It starts at 15,000
miles (24,140 km) and counts down to zero. Once it reaches zero the console will display SVC.
Service:
•
Replace the running belt and deck.
• Reset the service odometer. See below.
1. Press the STOP key several times.
2.
Press and the hold the Scan/Hold or Display option and DOWN keys for 3 seconds.
3.
Press the UP or DOWN keys until Svc in is displayed.
Total number of miles or kilometers in the service odometer will be displayed.
4.
Press the Scan/Hold or Display option key.
The console will display RESET no?. Pressing the ENTER or STOP key will exit without
resetting the service odometer.
5.
Press the UP or DOWN keys until RESET YES? is displayed.
6.
Press ENTER to reset the odometer to 15,000 miles or 24,140 kilometers.
7. Press STOP to exit diagnostic mode.
Exit error log
Exit by pressing the STOP key to return to Dormant Mode.
Software Update 625T
Software can ONLY be installed on the model it is designed for. Do NOT install this software on other
Arc Trainers, Bikes, or Treadmills.
Tools Required
• USB stick (CP-23199)
• Phillips screwdriver
Repairs and Service
• DO NOT load zip files onto USB stick
• Load un-zipped files onto USB stick
• DO NOT remove USB stick during upload procedure
• Power must remain on during upload procedure
• DO NOT press any keys on console during upload procedure
Prepare USB stick
1. Plug USB stick into PC.