Error 19: Drive Enable Line is open
Cause:
The Drive is reporting the enable line (used for E-Stop) is open by clearing bit 4 of the status byte, when
the MCC is not sensing the key is out.
Service:
Intermittent connection in the console cable is the most likely suspect.
Inspect each connection in this cable for loose terminals, unseated connectors, or pinched or abraded
wires.
Power outages are also suspect, either at the utility or anywhere from the panel to the treadmill (power
cord, treadmill’s inlet or power switch, floor/wall outlet, etc.)
If these are in good shape, monitoring the power over a week’s time may prove beneficial.
If the available power is not the issue, the drive itself or related cabling should be inspected and/or
replaced.