EasyManuals Logo

CYBEX 625T Service Manual

CYBEX 625T
209 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
Error 105: Thermal Integrator of Input Current (Drives with PFC only)
Cause:
The drive is measuring the heating effect of high input current.
110 VAC: >=23A starts the timer, 43A / 18 seconds based on I ²C
220 VAC: >=12.5A starts the timer, 25A / 18 seconds based on I²C
Service:
Verify line voltage isn’t sagging.
Check the belt/deck for wear.
Check treadmill for physical obstructions, seized bearings, etc.
Investigate actual line current with various weight users. Determine user weight, speed and incline
when error occurred.
Page 96 of 209
Cybex 625T Treadmill Part Number

Other manuals for CYBEX 625T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CYBEX 625T and is the answer not in the manual?

CYBEX 625T Specifications

General IconGeneral
User Weight Capacity400 lbs
Speed Range0.5 - 12.4 mph
Incline Range0% to 15%
DisplayLED
Heart Rate MonitoringContact and wireless
Running Area60" x 20" (152 x 51 cm)

Related product manuals