DES-3526 / DES-3526DC Layer 2 Fast Ethernet Switch CLI Reference Manual
59
create syslog host
Purpose Used to create a new syslog host.
Syntax
create syslog host <index 1-4> ipaddress <ipaddr> {severity [informational | warning |
all] | facility [local0 | local1 | local2 | local3 | local4 | local5 | local6 | local7] | udp_port
<udp_port_number> | state [enable | disable]
Description The create syslog host command is used to create a new syslog host.
<index 1-4> Specifies that the command will be applied to an index of hosts. There are
four available indexes, numbered 1 through 4.
ipaddress <ipaddr> Specifies the IP address of the remote host where syslog messages
will be sent.
severity Severity level indicator. These are described in the following:
Bold font indicates that the corresponding severity level is currently supported on the
Switch.
Numerical Severity
Code
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
Parameters
informational Specifies that informational messages will be sent to the remote host. This
corresponds to number 6 from the list above.
warning Specifies that warning messages will be sent to the remote host. This
corresponds to number 4 from the list above.
all Specifies that all of the currently supported syslog messages that are generated by the
Switch will be sent to the remote host.
facility Some of the operating system daemons and processes have been assigned
Facility values. Processes and daemons that have not been explicitly assigned a Facility
may use any of the "local use" facilities or they may use the "user-level" Facility. Those
Facilities that have been designated are shown in the following: Bold font indicates the
facility values that the Switch currently supports.