EasyManuals Logo

DAB E.sybox Instruction For Installation And Maintenance

DAB E.sybox
57 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
ENGLISH
GB
112
12 - DISPOSAL
This product or its parts must be disposed of in an environment-friendly
manner and in compliance with the local regulations concerning the envi-
ronment; use public or private local waste collection systems.
13 - GUARANTEE
Any use of faulty material or manufacturing defects of the appliance will
be eliminated during the guarantee period contemplated by the law in
force in the country where the product is purchased, by repair or replace-
ment, as we decide.
The guarantee covers all substantial defects that can be assigned to
manufacturing faults or to the material used if the product has been used
correctly, in accordance with the instructions.
The guarantee is void in the following cases:
DWWHPSWVWRUHSDLUWKHDSSOLDQFH
WHFKQLFDODOWHUDWLRQVWRWKHDSSOLDQFH
XVHRIQRQRULJLQDOVSDUHSDUWV
WDPSHULQJ
LQDSSURSULDWHXVHIRUH[DPSOHLQGXVWULDOXVH
Excluded from the guarantee:
SDUWVVXEMHFWWRUDSLGZHDU
When making a request under guarantee, apply to an authorised techni-
cal assistance service, presenting proof of purchase of the product.
The display
shows
BL
Red: on
White: on
Blue: off
1. No water.
2. Pump not primed.
3. Setpoint not reach-
able with the set
RM value
1-2. Prime the pump and check
whether there is air in the pipe.
Check whether the suction or any
¿OWHUVDUHEORFNHG
3. Set a RM value that allows the
setpoint to be reached.
The display
shows
BP1
Red: on
White: on
Blue: off
1. Faulty pressure
sensor.
1. Contact the assistance centre.
The display
shows
OC
Red: on
White: on
Blue: off
1. Excessive absorp-
tion.
2. Pump blocked.
1. Fluid too dense. Do not use
WKHSXPSIRUÀXLGVRWKHUWKDQ
water.
2. Contact the assistance centre.
The display
shows
LP
Red: on
White: on
Blue: off
1. Supply voltage
too low.
2. Excessive drop in
voltage on the line.
1. Check the presence of the cor-
rect supply voltage.
2. Check the section of the power
supply cables.
The display
shows:
Press + to
propagate
WKLVFRQ¿J
Red: off
White: on
Blue: off
One or more devices
have sensitive param-
eters not aligned.
Press the + key on the device
which we are sure has the most
UHFHQWDQGFRUUHFWFRQ¿JXUDWLRQRI
the parameters.

Other manuals for DAB E.sybox

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DAB E.sybox and is the answer not in the manual?

DAB E.sybox Specifications

General IconGeneral
BrandDAB
ModelE.sybox
CategoryWater Pump
LanguageEnglish

Related product manuals