022-00028AE Operation and Maintenance Manual Inspection, Maintenance and Adjustment 4-41
CLEAN FUEL INJECTION PRIMING PUMP STRAINER
1. Remove fitting, fuel line and strainer from
bottom of priming pump.
2. Clean strainer.
3. Position strainer in priming pump and
install fuel line and fitting.
REPLACE AIR CONDITIONER FILTER
NOTE:
This unit is equipped with an air filtration system which filters out dirt and dust particles
from air being circulated into operator’s cab. This filter should be cleaned out every 500
hours and replaced with a new one every 1,000 hours. For filter replace See “Clean Air
Conditioner Filter” on page 4-36.
NOTE:
In the event that the equipment is being operated in a dusty environment, the cleaning and
replacement should be performed more frequently.