User’s Manual
171
Post-Alarm
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 0 seconds to 300
seconds. If you enter 0, there will be no delay.
Show Message
Select the
checkbox to enable a pop-up alarm message
in your local host PC.
Report Alarm
Select the
checkbox to enable the system to upload the
alarm signal to the network (including alarm center) when an alarm
event occurs.
Not all models support this function.
The corresponding parameters in the alarm center should be
configured. For details, see "5.15.1.12
Settings."
Send Email
Select the
checkbox to enable the system to send an email
notification when an alarm event occurs.
To use this function, make sure the email function is enabled in
Main
Menu > NETWORK > Email
.
Record Channel
Select the channel(s) that you want to record. The selected channel(s)
starts recording after an alarm event occurs.
The recording for intelligence event and auto recording function must be
enabled. For details, see "5.1.4.9
Configuring Recorded Video Storage
Schedule" and "5.9.1 Enabling Record Control."
PTZ Linkage
Click
to display the PTZ page.
Enable PTZ linkage actions, such as selecting the preset that you want to
be called when an alarm event occurs.
To use this function, the PTZ operations must be configured. For details,
see "5.4 Controlling PTZ Cameras."
Post Record
Set a length of time for the Device to delay turning off recording after
the alarm is cancelled. The value ranges from 10 seconds to 300 seconds.
Tour
Select the
checkbox to enable a tour of the selected channels.
To use this function, the tour setting must be configured.
After the tour is ended, the live view screen returns to the view layout
before tour started.
Picture Storage
Select the
checkbox to take a snapshot of the selected
channel.
To use this function, make sure the snapshot function is enabled for
in
Main Menu > STORAGE > Schedule > Snapshot
.