1 General safety precautions
Installation and maintenance instructions
7
Daikin Altherma EHS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1444099_01 – 11/2018 – EN
KSK limescale and corrosion protector. For other properties deviat-
ing from the minimum requirements, suitable conditioning measures
are necessary to maintain the required water quality.
Using filling water and top-up water which does not meet the stated
quality requirements can cause a considerably reduced service life
of the device. The responsibility for this lies solely with the operator.
1.2.6 Heating system and sanitary connection
Create a heating system according to the safety requirements of
EN12828.
The plumbing connection must comply with the requirements of
EN12897. The requirements of the following must also be ob-
served
EN1717 – Protection against pollution of potable water installa-
tions and general requirements of devices to prevent pollution
by backflow.
EN61770 – Electric appliances connected to the water mains –
Avoidance of backsiphonage and failure of hose-sets.
EN806 – Specifications for installations inside buildings con-
veying water for human consumption (TRWI).
and, in addition, the country-specific legislation.
When operating the indoor unit with additional heat source, the stor-
age tank temperature may exceed 65°C, above all when solar en-
ergy is used.
For this reason, some form of scalding protection needs to be in-
cluded when you install the system (hot water mixing device, e.g.
VTA32).
If the indoor unit is connected to a heating system with steel pipes,
radiators or non-diffusion-proof floor heating pipes, sludge and chips
can enter the hot water storage tank and cause blockages, local
overheating or corrosion damage.
To prevent possible damage, install a dirt filter or sludge separator
into the heating return flow of the system (SAS 1 or SAS 2).
The dirt filter must be cleaned at regular intervals.
1.2.7 Operation
The indoor unit:
Do not operate until all installation and connection work is com-
pleted.
Only operate with a completely full storage tank (Level indicator)
and heating circuit.
Operate at a maximum pressure of 3bar.
Only connect with a pressure reducer on the external water supply
(supply line).
Only operate the with the specified quantity of coolant and the
type of coolant specified.
only operate if the protective cover is installed.
The specified servicing intervals should be adhered to and inspec-
tion work must be carried out.