9 | Electrical installation
Installer reference guide
114
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V
Daikin Altherma 3 H MT F
4P644482-1 – 2021.03
Item Description
Heat pump convector There are different controllers and setups
possible for the heat pump convectors.
Depending on the setup, you also need to
implement a relay (field supply, see
addendum book for optional equipment).
For more information, see:
▪ Installation manual of the heat pump
convectors
▪ Installation manual of the heat pump
convector options
▪ Addendum book for optional equipment
Wires: 0.75mm²
Maximum running current: 100mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
Remote outdoor sensor See:
▪ Installation manual of the remote outdoor
sensor
▪ Addendum book for optional equipment
Wires: 2×0.75mm²
[9.B.1]=1 (External sensor = Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Remote indoor sensor See:
▪ Installation manual of the remote indoor
sensor
▪ Addendum book for optional equipment
Wires: 2×0.75mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset