7 | Unit installation
Installer reference guide
69
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V
Daikin Altherma 3 H MT F
4P644482-1 – 2021.03
2 Remove the screws (5×) from the transportation stay. Remove the
transportation stay and dispose of it. Keep 4 screws to attach the compressor
cover piece (see the installation manual, topic “To attach the compressor
cover piece”).
7.2.4 To close the outdoor unit
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 4.1N•m.
1
1
2
32
4
4
3
3
1
7.2.5 To open the indoor unit
Overview
a
b
d
c
e
a Top panel
b User interface panel
c Switch box cover
d Front panel
e High voltage switch box cover