7 | Unit installation
Installer reference guide
76
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V
Daikin Altherma 3 H MT F
4P644482-1 – 2021.03
NOTICE
Provide at least 150mm of free space below the unit. Additionally, make sure the
unit is positioned at least 100mm above the expected level of snow.
Use the drain plug (with O-ring) and a hose for drainage.
1 2
a
b
c
c
3
d
a Drain hole
b O-ring (delivered as accessory)
c Drain plug (delivered as accessory)
d Hose (field supply)
NOTICE
O-ring. Make sure the O-ring is installed correctly to prevent leakage.
7.3.6 To install the discharge grille
INFORMATION
Electrical wiring. Before installing the discharge grille, connect the electrical wiring.
Install the lower part of the discharge grille
1 Insert the hooks.
2 Insert the ball studs.