11 | Configuration
Installer reference guide
137
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Schedule/Control Description
[5.5] Tank > Schedule
Schedule for the domestic hot
water tank temperature for
your normal domestic hot
water needs.
Predefined schedules: 1
Activation screen: Not applicable. This schedule
is automatically activated if the DHW mode is
one of the following:
▪ Schedule only
▪ Schedule + reheat
Possible actions:
▪ Comfort: When to start heating the tank to
the user-defined preset value [5.2] Comfort
setpoint.
▪ Eco: When to start heating the tank to the
user-defined preset value [5.3] Eco
setpoint.
▪ Stop: When to stop heating the tank, even if
the desired tank temperature is not reached
yet.
Note: In Schedule + reheat mode, the
system also takes the user-defined preset value
[5.4] Reheat setpoint into account.
[7.4.2] User settings >
Quiet > Schedule
Schedule for when the unit has
to use which quiet mode level.
Predefined schedules: 1
Activation screen: [7.4.1] Activation (only
available to installers).
Possible actions: You can use the following
system-defined preset values:
▪ Quiet
▪ More quiet
▪ Most quiet
See "About quiet mode"[4185].
[7.5.4] User settings >
Electricity price >
Schedule
Schedule for when a certain
electricity tariff is valid.
Predefined schedules: 1
Activation screen: Not applicable
Possible actions: You can use the following
system-defined preset values:
▪ High
▪ Medium
▪ Low
See "Setting the energy prices"[4142].
Restriction: Only available to
installers.
[9.4.2] Installer settings
> Booster heater > BSH
allowance schedule
Predefined schedules: 1
Activation screen: Not applicable
Possible actions: You can program 2 actions per
day.
▪ Off: Booster heater operation NOT allowed.
▪ On: Booster heater operation allowed.