6 | Application guidelines
Installer reference guide
52
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Configuration
The outdoor unit can control DHW pump operation. For more information, see
"11Configuration"[4123].
6.4.6 DHW pump for tank preheating
INFORMATION
Restriction: Only applicable in case of stainless steel tanks (EKHWS*D*).
Setup
b
c
a
d
ef
M
a DHW tank
b Cold water IN
c Hot water OUT (shower (field supply))
d Motorised 3‑way valve (field supply)
e DHW pump (field supply)
f Non‑return valve (field supply)
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see "To connect the domestic hot water
pump"[4113].
Configuration
The outdoor unit can control DHW pump operation. For more information, see
"11Configuration"[4123].
6.5 Setting up the energy metering
Via the user interface, you can read out the following energy data:
- Produced heat
- Consumed energy
You can read out the energy data:
- For space heating
- For space cooling
- For domestic hot water production