(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
[E-05]: Can the system prepare domestic hot water?
[E-06]: Is a domestic hot water tank installed in the system?
[E-07]: What kind of domestic hot water tank is installed?
In case of EKHWP, we recommend to use the following settings:
# Code Item EKHWP
[9.2.1] [E‑07] Tank type 5: EKHWP/HYC
N/A [4-05] Thermistor type 0: Automatic
[5.8] [6-0E] Maximum tank
temperature
≤70°C
In case of EKHWS*D* / EKHWSU*D*, we recommend to use the following settings:
# Code Item EKHWS*D* / EKHWSU*D*
[9.2.1] [E‑07] Tank type 0: EKHWS/E
N/A [4-05] Thermistor type 0: Automatic
[5.8] [6-0E] Maximum tank
temperature
≤75°C
In case of a third-party tank, we recommend to use the following settings:
# Code Item Third-party tank
[9.2.1] [E‑07] Tank type 0: EKHWS/E
N/A [4-05] Thermistor type 0: Automatic
[5.8] [6-0E] Maximum tank
temperature
≤75°C