15 | Troubleshooting
Installer reference guide
243
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Error code Description
H6-00 OU: Malfunction of position detection sensor
H8-00 OU: Malfunction of compressor input (CT)
system
H9-00 OU: Malfunction of outdoor air thermistor
HC-00 Tank temperature sensor problem
HC-01 Second tank temperature sensor problem
HJ-10 Water pressure sensor abnormality
J3-00 OU: Malfunction of discharge pipe thermistor
J3-10 Compressor port thermistor abnormality
J5-00 Malfunction of suction pipe thermistor
J6-00 OU: Malfunction of heat exchanger thermistor
J6-07 OU: Malfunction of heat exchanger thermistor
J6-32 Leaving water temperature thermistor
Abnormality (outdoor unit)
J6-33 Sensor communication error
J8-00 Malfunction of refrigerant liquid thermistor
JA-00 OU: Malfunction of high pressure sensor
JC-00 Low pressure sensor abnormality
JC-01 Evaporator pressure abnormality
L1-00 Malfunction of INV PCB
L3-00 OU: Electrical box temperature rise problem
L4-00 OU: Malfunction of inverter radiating fin
temperature rise
L5-00 OU: Inverter instantaneous overcurrent (DC)
L8-00 Malfunction triggered by a thermal protection
in the inverter PCB
L9-00 Prevention of compressor lock
LC-00 Malfunction in communication system of outdoor
unit
P1-00 Open-phase power supply imbalance
P3-00 Abnormal direct current
P4-00 OU: Malfunction of radiating fin temperature
sensor
PJ-00 Capacity setting mismatch
U0-00 OU: Shortage of refrigerant
U1-00 Malfunction by reverse phase/open-phase

Table of Contents