9 | Electrical installation
Installer reference guide
93
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Item Description
Room thermostat (wired or
wireless)
In case of wireless room thermostat, see:
Installation manual of the wireless room
thermostat
Addendum book for optional equipment
In case of wired room thermostat without
multi-zoning base unit, see:
Installation manual of the wired room
thermostat
Addendum book for optional equipment
In case of wired room thermostat with
multi-zoning base unit, see:
Installation manual of the wired room
thermostat (digital or analogue) + multi-
zoning base unit
Addendum book for optional equipment
In this case:
- You need to connect the wired room
thermostat (digital or analogue) to the
multi-zoning base unit
- You need to connect the multi-zoning
base unit to the outdoor unit
- For cooling/heating operation, you also
need to implement a relay (field supply,
see addendum book for optional
equipment)
Wires: 0.75mm²
Maximum running current: 100mA
For the main zone:
[2.9] Control
[2.A] Thermostat type
For the additional zone:
[3.A] Thermostat type
[3.9] (read-only) Control