Breadcrumb Field code Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
Setting name
A.8 [B-00]
0
A.8 [B-01]
0
A.8 [B-02]
0
A.8 [B-03]
0
A.8 [B-04]
0
A.8 [C-00] R/W
0: Solar priority
1: Heat
p
um
p
p
riorit
y
A.8 [C-01]
0
A.8 [C-02]
0
A.8 [C-03]
0
A.8 [C-04]
3
A.8 [C-05] R/W 1: Thermo ON/OFF
2: C/H re
q
ues
t
A.8 [C-06] R/W 0: -
1: Thermo ON/OFF
2: C/H re
q
ues
t
A.8 [C-07] R/W 0: LWT control
1: Ext RT control
2: RT control
A.8 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.8 [C-09] R/W
0: Normally open
1: Normall
y
closed
A.8 [C-0A] R/W
0: Disable
1: Enable
A.8 [C-0C] R/W 0~7
4
A.8 [C-0D] R/W 0~7
4
A.8 [C-0E] R/W 0~7
4
A.8 [D-00]
0
A.8 [D-01] R/W
0: No
1: Open tariff
2: Closed tariff
3: Thermostat
A.8 [D-02] R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
A.8 [D-03] R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C
(
from -4 to 4°C
)
A.8 [D-04] R/W
0: No
1: Pwr consm
p
ctrl
A.8 [D-05]
1
A.8 [D-07] R/W
0: No
1: Yes
A.8 [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8 [D-09]
0
A.8 [D-0A] R/W
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
A.8 [D-0B]
2
A.8 [D-0C] R/W 0~49
20
A.8 [D-0D] R/W 0~49
20
A.8 [D-0E] R/W 0~49
15
A.8 [E-00] R/O
0~5
3: H
y
brid
A.8 [E-01] R/O
0: 08
A.8 [E-02] R/O
EHYHBH05+08: 1: Type 2
EHYHBX08: 0: T
yp
e 1
A.8 [E-03]
0
A.8 [E-04] R/O
1: Yes
A.8 [E-05] R/W
0: No
1: Yes
A.8 [E-06] R/W
0: No
1: Yes
A.8 [E-07] R/W
0~6
4: Type 5
6: Type 7
A.8 [E-08] R/W 0: Disabled
1: Enabled
A.8 [E-09]
0
A.8 [E-0A]
0
A.8 [E-0B]
0
A.8 [E-0C]
0
A.8 [E-0D]
0
A.8 [F-00] R/W
0: Disabled
1: Enabled
A.8 [F-01] R/W 10~35°C, step: 1°C
20°C
A.8 [F-02]
3
A.8 [F-03]
5
A.8 [F-04]
0
A.8 [F-05]
0
A.8 [F-06]
0
A.8 [F-09] R/W
0: Disabled
1: Enabled
A.8 [F-0A]
0
A.8 [F-0B] R/W
0: No
1: Yes
--
--
--
--
--
High electricity price decimal (Do not use)
Domestic heating water priority.
--
--
--
--
What is the thermo request contact type for the main zone?
Medium electricity price decimal (Do not use)
Low electricity price decimal (Do not use)
--
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
Indoor quick heat-up function
Which type of compressor is installed?
Is a demand PCB connected?
--
Is a solar kit connected?
Is an external kWh meter used for power measurement?
--
Is an external gas meter used for power measurement?
--
Is the power saving function available on the outdoor unit?
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
--
What is the high electricity price (Do not use)
What is the medium electricity price (Do not use)
What is the low electricity price (Do not use)
Which type of unit is installed?
--
Power saving function for outdoor unit.
--
--
--
Pump operation allowed outside range.
--
Forced off contact type
--
What is the indoor unit software type?
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Above which outdoor temperature is cooling allowed?
--
--
--
--