Breadcrumb Field code Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
Setting name
A.8 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
A.8 [5-0A] R/W 0~20 kW, step: 0,5 kW
20 kW
A.8 [5-0B] R/W 0~20 kW, step: 0,5 kW
20 kW
A.8 [5-0C] R/W 0~20 kW, step: 0,5 kW
20 kW
A.8 [5-0D]
1
A.8 [5-0E]
0
A.8 [6-00] R/W 2~20°C, step: 1°C
2°C
A.8 [6-01] R/W 0~10°C, step: 1°C
2°C
A.8 [6-02]
0
A.8 [6-03]
0
A.8 [6-04]
0
A.8 [6-05]
0
A.8 [6-06]
0
A.8 [6-07]
0
A.8 [6-08] R/W
2~20°C, step: 1°C
5°C
A.8 [6-09]
0
A.8 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
A.8 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
50°C
A.8 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
50°C
A.8 [6-0D]
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
A.8 [6-0E] R/W [E-06]=1:
[E-07]
6:
40~75°C, step: 1°C, 75°C
[E-07]=6: 40~60°C, step: 1°C, 60°C
[E-06]=0:
40~65°C
,
ste
p
: 1°C
,
65°C
A.8 [7-00]
0
A.8 [7-01]
2
A.8 [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
A.8 [7-03] R/W 0~6, step: 0,1
2,5
A.8 [7-04] R/W
0: Economical
1: Ecolo
g
ical
A.8 [7-05]
0
A.8 [8-00]
1
A.8 [8-01] R/W 5~95 min, step: 5 min
30 min
A.8 [8-02] R/W 0~10 hour, step: 0,5 hour
1,5 hour
A.8 [8-03]
50
A.8 [8-04]
0
A.8 [8-05] R/W 0: No
1: Yes
A.8 [8-06] R/W 0~10°C, step: 1°C
5°C
A.8 [8-07] R/W [9-03]~[9-02]°C, step: 1°C
18°C
A.8 [8-08] R/W [9-03]~[9-02]°C, step: 1°C
20°C
A.8 [8-09] R/W [9-01]~[9-00]°C, step: 1°C
45°C
A.8 [8-0A] R/W [9-01]~[9-00]°C, step: 1°C
40°C
A.8 [8-0B] R/W 10~20, step: 0,5
EHYHBH05: 13
EHYHBH/X08: 15
A.8 [8-0C] R/W 10~20, step: 0,5
EHYHBH05: 13
EHYHBH/X08: 15
A.8 [8-0D] R/W
10~20, step: 0,5
16
A.8 [9-00] R/W 37~80°C, step: 1°C
80°C
A.8 [9-01] R/W 15~37°C, step: 1°C
25°C
A.8 [9-02] R/W 18~22°C, step: 1°C
22°C
A.8 [9-03] R/W 5~18°C, step: 1°C
5°C
A.8 [9-04]
1
A.8 [9-05] R/W 15~37°C, step: 1°C
25°C
A.8 [9-06] R/W 37~80°C, step: 1°C
80°C
A.8 [9-07] R/W 5~18°C, step: 1°C
5°C
A.8 [9-08] R/W 18~22°C, step: 1°C
22°C
A.8 [9-09]
5
A.8 [9-0A]
5
A.8 [9-0B] R/W
0: Quick
1: Slow
A.8 [9-0C] R/W 1~6°C, step: 0,5°C
1°C
A.8 [9-0D] R/W 0~8,step:1
6
A.8 [9-0E] 0~8,step:1
6
A.8 [A-00]
0
A.8 [A-01]
0
A.8 [A-02]
0
A.8 [A-03]
0
A.8 [A-04]
0
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
--
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
--
--
--
--
--
--
What is the hysteresis to be used in reheat mode?
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
What is the maximum temperature setpoint?
--
--
How many leaving water temperature zones are there?
PE factor
Savings mode
--
--
Maximum running time for domestic hot water operation.
Anti-recycling time.
--
--
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
Target flow rate during HP mode
Target flow rate during hybrid mode
Target flow rate during boiler mode
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the mimimum desired LWT for main zone in cooling?
--
What is the mimimum desired LWT for add. zone in heating?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
--
--
What emitter type is connected to the main LWT zone?
Room temperature hysteresis.
Pump speed limitation
--
--
--
--
--
--