EasyManua.ls Logo

Daikin Altherma EKHBH(X)008AA - 4 Dimensional Drawing & Centre of Gravity; Dimensional Drawing

Daikin Altherma EKHBH(X)008AA
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
•Altherma
TM
• Domestic hot water tank
243
Domestic hot water tank • EKHWS-B
4 Dimensional drawing & centre of gravity
4 - 1 Dimensional drawing
4
4
3TW57944-1
EKHWS-B
j
1
Water mains in G 3/4 (Female)
j
2
Water mains out G 3/4 (Female)
j
3
Thermistor connection
j
4
Flow (from EKHB(H/X)*) G 3/4 (Female)
j
5
Return (to EKHB(H/X)*) G 3/4 (Female)
j
6
Switchbox
j
7
Thermal protector
j
8
Anode
j
9
Cable entry: power, booster heater and thermal protection cable
j
10
Re-circulation connection: G 3/4 (Female)
j
11
Cable entry for EKSOLHWAV1: power supply from EKHB(H/X)
j
12
Cable entry for EKSOLHWAV1: power supply to EKSOLHWAV1
pump
j
13
Thermistor connection (See EKSOLHWAV1)
j
14
3 way valve
Required service space around the
tank
3 way valve
EKHWSU-B
Water connections kit
j
9
Pressure reducing valve 22MM-22MM
j
10
Expansion relief valve 22MM-22MM
j
11
T-piece (to tundish) 15MM-15MM-G 1/2 (Female)
j
12
Tundish 22MM-15MM
j
13
T-piece (to expansion vessel) 22MM-22MM-22MM
j
14
Adapter (expansion vessel) 22MM-G 3/4 (Female)
j
15
Expansion vessel G 3/4 (Male)
j
16
Drain valve 22MM-G 2/4 (Female)
j
17
Solenoid valve 3/4’’ female BSP-3/4’’ hale BSP
Water connections
j
1
Water IN (cold) 22MM
j
2
Water OUT (hot) G 3/4 (Female)
j
3
Flow from EKHB(H/X)* G 3/4 (Female)
j
4
Return to EKHB(H/X)* G 3/4 (Female)
j
5
Temperature relief valve 15MM
j
6
Thermistor connection
j
7
Thermistor connection (
See EKSOLHWAV1)
G 1/2 (Female)
j
8
Re-circulation hole G 3/4 (Combinations
compliant to NF-PAC)
Other
j
18
EKUHW2WB kit: solenoid valve (only with EKSOLHWAV1) Rp 3/4 - Rp 3/4
j
19
Switchbox
j
20
Thermal protector 1+Thermostat
j
21
Cable entry: power supply booster heater and thermal protector cable
j
22
Cable entry for EKUHW2WB: power supply to solenoid valve
j
23
Cable entry: power supply booster heater and thermal protector cable
j
24
Blind stop + 2 plastic screw-on closing caps for pressure reducing valve
j
25
Thermal protector 2+Thermostat
j
26
Cable entry for EKSOLHWAV1: power supply to EKSOLHWAV1 pump
j
27
3 way valve 3x Rp1
Typical installation EKUHWA-kit
Required service space
3TW57944-2A
Model H1 H2 H3 H4
EKHWSU150B3V3 900 1015 255 130
EKHWSU200B3V3 1150 1265 410 200
EKHWSU300B3V3 1600 1715 410 200

Table of Contents