Indoor units • EKHBH-X008AA
•Altherma
TM
• Indoor units
24
2 Specifications
1
2
Operation
range
Ambient Heating °C -20~25
Cooling °C 10~43
Waterside Heating °C 15~50
Cooling °C 5~22
2-2 ELECTRICAL SPECIFICATIONS EKHBH008AA EKHBX0008AA
Electric heater Type 3V3
Power Supply Phase 1~
Frequenc
y
Hz 50 50
Voltage V 230 230
Current Running
Current
A13 13
Current Z-max List No requirements
Zmax electric
heater +
booster heater
(EKSWW*
Models)
Text 0.25 + j0.15
Electric heater Current Minimum Ssc value Equipment complying with EN/IEC 61000-3-12
Voltage range Minimum -10%
Maximum +10%
Wiring
connections
For power
supply backup
heater
Quantity of wires 3G
Type of wires Select diameter and type according to national and local regulations
Electric heater Type 6V3
Power Supply Phase 1~
Frequenc
y
Hz 50 50
Voltage V 230 230
Current Running
Current
A26 26
Current Z-max Text 0.25 + j0.15
Zmax electric
heater +
booster heater
(EKSWW*
Models)
Text 0.15 + j0.09
Electric heater Current Minimum Ssc value Equipment complying with EN/IEC 61000-3-12
Voltage range Minimum -10%
Maximum +10%
Wiring
connections
For power
supply backup
heater
Quantity of wires 3G
Type of wires Select diameter and type according to national and local regulations
Electric heater Type 6WN
Power Supply Phase 3~
Frequenc
y
Hz 50 50
Voltage V 400 400
Current Running
Current
A8.7 8.7
Current Z-max List No requirements
Zmax electric
heater +
booster heater
(EKSWW*
Models)
List No requirements
Electric heater Current Minimum Ssc value Equipment complying with EN/IEC 61000-3-12
Voltage range Minimum -10%
Maximum +10%
2-1 TECHNICAL SPECIFICATIONS EKHBH008AA EKHBX0008AA