25
Indoor units • EKHBH-X008AA
2 Specifications
1
2
Wiring
connections
For power
supply backup
heater
Quantity of wires 4G
Type of wires Select diameter and type according to national and local regulations
Electric heater Type 6T1
Power Supply Phase 3~
Frequenc
y
Hz 50 50
Voltage V 230 230
Current Running
Current
A 15.1 15.1
Current Z-max List Out of scope
Zmax electric
heater +
booster heater
(EKSWW*
Models)
List Out of scope
Electric heater Current Minimum Ssc value Equipment complying with EN/IEC 61000-3-12
Voltage range Minimum -10%
Maximum +10%
Wiring
connections
For power
supply backup
heater
Quantity of wires 4G
Type of wires Select diameter and type according to national and local regulations
Electric heater Type 9WN
Power Supply Phase 3~
Frequenc
y
Hz 50 50
Voltage V 400 400
Current Running
Current
A13 13
Current Z-max List No requirements
Zmax electric
heater +
booster heater
(EKSWW*
Models)
List No requirements
Electric heater Current Minimum Ssc value Equipment complying with EN/IEC 61000-3-12
Voltage range Minimum -10%
Maximum +10%
Wiring
connections
For power
supply backup
heater
Quantity of wires 4G
Type of wires Select diameter and type according to national and local regulations
Electric heater Type 9T1
Power Supply Phase 3~
Frequenc
y
Hz 50 50
Voltage V 230 230
Current Running
Current
A 22.6 22.6
Current Z-max List Out of scope
Zmax electric
heater +
booster heater
(EKSWW*
Models)
List Out of scope
Electric heater Current Minimum Ssc value Equipment complying with EN/IEC 61000-3-12
Voltage range Minimum -10%
Maximum +10%
2-2 ELECTRICAL SPECIFICATIONS EKHBH008AA EKHBX0008AA