Loading...
Outdoor units • ERHQ006-008AD
•Altherma
TM
• Outdoor units
12
2 Specifications
1
2
Heat
Exchanger
Dimensions Length mm 845 845 845
Nr of Rows 2 2 2
Fin Pitch mm 1.8 1.8 1.8
Nr of Stages 32 32 32
Tube type Hi-Xa(8)
Fin Type WF fin
Treatment Anti-corrosion treatment (PE)
Fan Type Propeller
Quantity 111
Discharge direction Horizontal
Motor Quantity 1 1 1
Output W 53 53 53
CompressorQuantity 111
Motor Model 2YC63BXD#C
Type Hermetically sealed swing compressor
Motor
Output
W 1,920
Operation
Range
Heating Min °CWB -20 -20 -20
Max °CWB 25 25 25
Cooling Min °CDB 10 10 10
Max °CDB 43 43 43
Sanitary water Min °CDB -20 -20 -20
Max °CDB 43 43 43
Sound Level
(nominal)
Heating Sound
Power
dBA 61 61 62
Sound
Pressure
dBA 48 48 49
Cooling Sound
Power
dBA 63 63 63
Sound
Pressure
dBA 48 48 50
Refrigerant Type R-410A
Charge kg 1.7 1.7 1.7
Control Expansion valve(electronic type)
Nr of Circuits 1 1 1
Refrigerant Oil Type FVC50K
Charged Volume l 0.75 0.75 0.75
Piping
connections
Liquid (OD) Type Flare connection
Diameter
(OD)
mm 6,35
Gas Type Flare connection
Diameter
(OD)
mm 15,9
Drain Quantity 1 1 1
Type Socket
Diameter
(OD)
mm 18 18 18
Piping Length Minimum m 3 3 3
Maximum m 30 30 30
Additional Refrigerant
Charge
kg/m 0.02>10m
Max. internunit level
difference
m20 20 20
Defrost Method Reverse cycle
Defrost Control Sensor for outdoor heat exchanger temperature
Capacity Control Method Inverter controlled
2-2 TECHNICAL SPECIFICATIONS ERHQ006AD ERHQ007AD ERHQ008AD