EasyManua.ls Logo

Daikin Altherma EKHBH(X)016AB - Electrical Specifications

Daikin Altherma EKHBH(X)016AB
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
•Altherma
TM
• Monobloc
201
Monobloc • EBLQ011-016AA6V3
2 Specifications
3
2
Expansion vessel Volume l 10 10 10
Maximum water pressure bar 3 3 3
Pre pressure bar 1.0 1.0 1.0
Water filter Diameter perforations mm 1 1 1
Material Brass
Water circuit Piping connections inch G5/4 (FEMALE)
Piping inch 5/4"
Safety valve bar 3 3 3
Manometer Yes
Drain valve / Fill valve yes
Shut off valve yes
Air purge valve yes
Total water volume (6) l 5.5 5.5 5.5
2-4 ELECTRICAL SPECIFICATIONS EBLQ011AA6V3 EBLQ014AA6V3 EBLQ016AA6V3
Power supply
compressor
component
Main Power Name V3
Phase 1 1 1
Frequency Hz 50 50 50
Voltage V 230 230 230
Voltage range Minimum V -10%
Maximum V +10%
Current Minimum Ssc
value
kVa Equipment complying with EN/IEC 61000-3-12(×)
Current Maximum running
current
Cooling A 22.8 27.4 31.9
Power supply
compressor
component
Current Recomende
d fuses
A32 32 32
Wiring connections For power supply
compressor component
See installation manual
Power supply
hydraulic
component
Current back-up
heater
Type 6V3
Current back-up
heater
Power Supply Phase 1~
Frequency Hz 50 50 50
Voltage V 230 230 230
Running Current Back-up
heater
A26 26 26
Running Current Back-up heater +
booster heater
+EK*V3 A 39(26+13)
Current back-up
heater
Z-max Back-up
heater
A 0.29 0.29 0.29
Back-up
heater +
booster
heater
A 0.17 0.17 0.17
Minimum Ssc value +EK*V3 kVa Equipment complying with EN/IEC 61000-3-12(**)
2-3 MAIN COMPONENTS EBLQ011AA6V3 EBLQ014AA6V3 EBLQ016AA6V3

Table of Contents