Monobloc • EBLQ011-016AA6V3
•Altherma
TM
• Monobloc
202
2 Specifications
3
2
Power supply
hydraulic
component
Voltage range Minimum V -10%
Maximum V +10%
Wiring connections Connection type for power supply hydraulic compartment
Quantity of wires 3G
Type of wires Select diameter and type according to national and local regulations
Connection type for power supply connection to optional sanitary tank + Q2L
Quantity of wires 3G
Type of wires Select diameter and type according to national and local regulations
Type of wires For more details on voltage range and current refer to installation manual
Connection type for connection with R5T
Quantity of wires Wire included in option EKHWS*
Type of wires Wire included in option EKHWS*
Connection type for connection with A3P
Quantity of wires Depends on thermostat type, refer to installation manual
Type of wires Select diameter and type according to national and local regulations
Type of wires Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
Connection type for connection with M2S
Quantity of wires 3G
Type of wires Select diameter and type according to national and local regulations
Type of wires Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
Connection type for connection with M3S
Quantity of wires 3G or 4G
Type of wires Select diameter and type according to national and local regulations
Type of wires Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
Notes Power supply compressor compartment is for compressor, fan, pump and controller
In accordance with EN/IEC 61000-3-11 (1), it may be necessary to consult the distribution network
operator to ensure that the equipment is connected only to a supply with Zsys (3) smaller than or equal
to Zmax.
Installer can reduce capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A.
Instructions see installation manual.
Installer can reduce capacity of the heater from 6 to 3.5kW. The current is then reduced from 8.7 to
5A. Instructions see installation manual.
(1)European/International Technical Standard setting the limits for voltage changes , voltage
fluctuations and flicker in public low-voltage supply systems for equipment with rated current <= 75A.
(2) European/International Technical Standard setting the limits for harmonic currents produced by
equipment connected to public low-voltage systems with input current > 16A =< 75A per phase.
(3) System impedance
Power supply hydraulic compartment is for the electric heater. The optional domestic warm water tank
has a separate power supply.
Conditions: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
2-4 ELECTRICAL SPECIFICATIONS EBLQ011AA6V3 EBLQ014AA6V3 EBLQ016AA6V3