Monobloc • EDHQ011-016AA6V3
2 Specifications
3
2
2-4 ELECTRICAL SPECIFICATIONS EDHQ011AA6V3 EDHQ014AA6V3 EDHQ016AA6V3
Power supply
compressor
component
Main Power Name V3
Phase 1 1 1
Frequency Hz 50 50 50
Voltage V 230 230 230
Voltage range Minimum V -10%
Maximum V +10%
Current Minimum Ssc
value
kVa Equipment complying with EN/IEC 61000-3-12(*)
Recomended
fuses
A32 32 32
Wiring connections For power supply
compressor component
See installation manual
Power supply
hydraulic component
Current back-up
heater
Type 6V3
Current back-up
heater
Power Supply Phase 1~
Frequency Hz 50 50 50
Voltage V 230 230 230
Running Current Back-up
heater
A26 26 26
Running Current Back-up heater +
booster heater
+EK*V3 A 39(26+13)
Current back-up
heater
Z-max Back-up
heater
A 0.29 0.29 0.29
Back-up
heater +
booster
heater
A 0.17 0.17 0.17
Minimum Ssc value +EK*V3 kVa Equipment complying with EN/IEC 61000-3-12(**)