10 | Configuration
Installer reference guide
216
EPRA14~18DAV3+W1 + ETVH16SU18+23EA6V
Daikin Altherma 3 H HT F
4P644738-1 – 2021.02
NOTICE
Forced defrost start-up. You can only start forced defrost when the heating
operation has been running for a while.
Overview field settings
Almost all settings can be done using the menu structure. If for any reason it is
required to change a setting using the overview settings, then the overview
settings can be accessed in the field settings overview [9.I]. See "To modify an
overview setting"[4136].
Export MMI settings
About exporting the configuration settings
Export the configuration settings of the unit to a USB memory stick, via the MMI
(the user interface of the indoor unit). When troubleshooting, these settings can
be provided to our Service department.
# Code Description
[9.N] N/A Your MMI settings will be exported
to the connected storage device:
▪ Back
▪ OK
To export MMI settings
1 Open the user interface panel and insert a USB memory stick.
—
2 On the user interface, go to [9.N] Export MMI settings.
3 Select OK.
4 Remove the USB memory stick and close the user interface
panel.
—