EasyManua.ls Logo

Daikin Altherma F - Page 217

Daikin Altherma F
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 | Configuration
Installer reference guide
217
EPRA14~18DAV3+W1 + ETVH16SU18+23EA6V
Daikin Altherma 3 H HT F
4P644738-1 – 2021.02
Bizone kit
Bizone kit installed
# Code Description
[9.P.1] [E-0B] Bizone kit installed:
0 No : The system only has a main zone.
1 N/A
2 Yes: A bizone kit is installed in order to add
an additional temperature zone.
Bizone kit system type
# Code Description
[9.P.2] [E-0C] Bizone system type
0 Without hydraulic separator / no
direct pump
b
a
1 With hydraulic separator / no
direct pump
b
a
c
2 With hydraulic separator / with
direct pump
dc
b
a
a:Indoor unit; b:Mixing station; c:Hydraulic
separator; d:Direct pump
Additional zone pump fixed PWM
The speed of the additional zone pump can be fixed with this setting.

Table of Contents

Related product manuals