SiUS181305E Function of CTXS, FTXS, CDXS, FDXS Series
Function 62
7. Function of CTXS, FTXS, CDXS, FDXS Series
7.1 Temperature Control
Definitions of
Temperatures
The definitions of temperatures are classified as following.
Room temperature: temperature of lower part of the room
Set temperature: temperature set by remote controller
Room thermistor temperature: temperature detected by room temperature thermistor
Target temperature: temperature determined by microcomputer
The illustration is for CTXS/FTXS series as representative.
Temperature
Control
The temperature of the room is detected by the room temperature thermistor. However, there is
difference between the temperature detected by room temperature thermistor and the temperature
of lower part of the room, depending on the type of the indoor unit or installation condition.
Practically, the temperature control is done by the target temperature appropriately adjusted for the
indoor unit and the temperature detected by room temperature thermistor.
Target temperature
Set temperature
Room temperature
Room thermistor temperature
(R12321)