EasyManua.ls Logo

Daikin Comfora - About the documentation; About this document; User Safety Instructions; Instructions for Safe Operation

Daikin Comfora
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of contents
Installer reference guide
2
FTXTP-M_FTXTP-N
Daikin room air conditioner
4P728168-4 – 2023.03
Table of contents
1 About the documentation 4
1.1 About this document ...................................................................................................................................................... 4
1.1.1 Meaning of warnings and symbols ................................................................................................................ 5
2 General safety precautions 7
2.1 For the installer............................................................................................................................................................... 7
2.1.1 General ........................................................................................................................................................... 7
2.1.2 Installation site ............................................................................................................................................... 8
2.1.3 Refrigerant — in case of R410A or R32.......................................................................................................... 11
2.1.4 Electrical ......................................................................................................................................................... 12
3 Specific installer safety instructions 15
4 About the box 17
4.1 Indoor unit ...................................................................................................................................................................... 17
4.1.1 To unpack the indoor unit.............................................................................................................................. 17
4.1.2 To remove the accessories from the indoor unit .......................................................................................... 17
5 About the unit 19
5.1 System layout.................................................................................................................................................................. 19
5.2 Operation range.............................................................................................................................................................. 19
5.3 About the wireless LAN................................................................................................................................................... 19
5.3.1 Precautions when using the wireless LAN ..................................................................................................... 20
5.3.2 Basic parameters ............................................................................................................................................ 20
6 Unit installation 21
6.1 Preparing the installation site......................................................................................................................................... 21
6.1.1 Installation site requirements of the indoor unit .......................................................................................... 21
6.2 Opening the unit ............................................................................................................................................................. 22
6.2.1 To remove the front panel ............................................................................................................................. 22
6.2.2 To open the service cover .............................................................................................................................. 23
6.2.3 To remove the front grille .............................................................................................................................. 23
6.3 Mounting the indoor unit ............................................................................................................................................... 24
6.3.1 To install the mounting plate ......................................................................................................................... 24
6.3.2 To drill a wall hole........................................................................................................................................... 25
6.3.3 To remove the pipe port cover ...................................................................................................................... 25
6.4 Connecting the drain piping ........................................................................................................................................... 26
6.4.1 General guidelines.......................................................................................................................................... 26
6.4.2 To connect the piping on right side, right-back, or right-bottom ................................................................. 27
6.4.3 To connect the piping on left side, left-back, or left-bottom........................................................................ 28
6.4.4 To check for water leaks................................................................................................................................. 29
7 Piping installation 30
7.1 Preparing refrigerant piping ........................................................................................................................................... 30
7.1.1 Refrigerant piping requirements.................................................................................................................... 30
7.1.2 Refrigerant piping insulation.......................................................................................................................... 31
7.2 Connecting the refrigerant piping .................................................................................................................................. 31
7.2.1 About connecting the refrigerant piping ....................................................................................................... 31
7.2.2 Precautions when connecting the refrigerant piping.................................................................................... 31
7.2.3 Guidelines when connecting the refrigerant piping...................................................................................... 32
7.2.4 Pipe bending guidelines ................................................................................................................................. 33
7.2.5 To flare the pipe end ...................................................................................................................................... 33
7.2.6 To connect the refrigerant piping to the indoor unit .................................................................................... 34
7.2.7 To check refrigerant piping joints for leaks after charging refrigerant ......................................................... 34
8 Electrical installation 36
8.1 About connecting the electrical wiring .......................................................................................................................... 36
8.1.1 Precautions when connecting the electrical wiring....................................................................................... 36
8.1.2 Guidelines when connecting the electrical wiring......................................................................................... 37
8.1.3 Specifications of standard wiring components.............................................................................................. 39
8.2 To connect the electrical wiring to the indoor unit ....................................................................................................... 39
9 Finishing the indoor unit installation 41
9.1 To insulate the drain piping, refrigerant piping and interconnection cable.................................................................. 41
9.2 To pass the pipes through the wall hole ........................................................................................................................ 41
9.3 To fix the unit on the mounting plate ............................................................................................................................ 42
9.4 Closing the unit ............................................................................................................................................................... 42

Table of Contents

Other manuals for Daikin Comfora

Related product manuals