EasyManua.ls Logo

Daikin ERRQ 016AAY1 - Page 4

Daikin ERRQ 016AAY1
262 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ESIE09-08
ii Table of Contents
2.2 Compressor PI Control...........................................................................50
2.3 Electronic Expansion Valve PI Control R-410A circuit ...........................51
2.4 Electronic Expansion Valve PI Control R-134a circuit............................51
3. Special Control......................................................................................52
3.1 Startup Control .......................................................................................52
3.2 Defrosting Operation ..............................................................................53
3.3 Pump-down Residual Operation ............................................................54
3.4 Stopping Operation ................................................................................55
4. Protection Control .................................................................................56
4.1 High Pressure Protection Control...........................................................56
4.2 Low Pressure Protection Control............................................................58
4.3 Discharge Pipe Protection Control .........................................................60
4.4 Inverter Protection Control .....................................................................61
5. Other Control.........................................................................................63
5.1 Heating Operation Prohibition ................................................................63
5.2 Inverter Fan Control (Switch Box Fan) ...................................................63
5.3 Crankcase Heater ..................................................................................63
6. Outline of Control (Indoor Unit) .............................................................64
6.1 Freeze Prevention ..................................................................................64
6.2 Simultaneous demand of space heating and domestic water heating ...65
Part 6 - Test Operation................................................................. 71
1. Test Operation ......................................................................................72
1.1 Procedure and Outline ...........................................................................72
1.2 Air Tight Test and Vacuum Drying .........................................................74
1.3 Additional Refrigerant Charge ................................................................75
1.4 Operation when Power is Turned On .....................................................79
2. Outdoor Unit PC Board Layout .............................................................80
3. Field Setting ..........................................................................................81
3.1 Field Setting from remote control ...........................................................81
3.2 Field Setting from Outdoor Unit............................................................104
Part 7 - Troubleshooting............................................................. 115
1. Symptom-based Troubleshooting .......................................................117
2. Troubleshooting by Remote Control ...................................................119
2.1 The INSPECTION / TEST Button.........................................................119
2.2 Self-diagnosis by Wired Remote Control .............................................120
2.3 Operation of the Remote Controller’s Inspection / Test Operation
Button ...................................................................................................121
2.4 Remote Control Service Mode .............................................................122
2.5 Remote Controller Self-Diagnosis Function .........................................124
3. Troubleshooting by Indication on the Remote Controller ....................130
3.1 “A1” Indoor Unit: PC Board Defect .......................................................130
3.2 “A6” Indoor Unit: Pump Error (M1P) or Other Water System Error ......131
3.3 “A9” Indoor Unit: Malfunction of Moving Part of Electronic Expansion
Valve (K1E) R-410A circuit...................................................................132
3.4 “AJ” Indoor Unit: Malfunction of Capacity Determination Device .........134
3.5 “C1” Indoor Unit: Failure of Transmission (Between Indoor unit PC Board
and Control PC Board) .........................................................................135
3.6 “C4” Indoor Unit: Malfunction of Thermistor (R3T) Liquid Thermistor R-

Table of Contents

Related product manuals