SiMT041509E Piping Diagrams
Appendix 98
1.2 Outdoor Unit
RKM18PVMK
RKM24PVMK
OUTDOOR UNIT
HEAT EXCHANGER
7.9 CuT
7.9 CuT
12.7 CuT
7.9 CuT7.9 CuT 6.4 CuT
STRAINER
DC FAN MOTOR
M
PROPELLER FAN
RECEIVER
6.4 CuT
12.7 CuT
12.7CuT
6.4 CuT
MUFFLER
9.5 CuT
7.9 CuT
HPS
MUFFLER
6.4 CuT
12.7 CuT
9.5 CuT
12.7 CuT
REFRIGERANT FLOW
12.7 CuT
COMPRESSOR
ACCUMULATOR
COOLING
FIELD PIPING
LIQUID (6.4 CuT)
FIELD PIPING
GAS (12.7 CuT)
LIQUID LINE
STOP VALVE
GAS LINE
STOP VALVE
MUFFLER
WITH
FILTER
MOTOR
OPERATED
VALVE
MUFFLER
WITH
FILTER
HEAT EXCHANGER (CONDENSER)
THERMISTOR
OUTDOOR TEMPERATURE
THERMISTOR
4-WAY
VALVE
DISCHARGE PIPE
THERMISTOR
3D092780
OUTDOOR UNIT
HEAT EXCHANGER
7.9 CuT
7.9 CuT
12.7 CuT
7.9 CuT
9.5 CuT 6.4 CuT 6.4 CuT
STRAINER
7.9 CuT
M
6.4 CuT
12.7 CuT
12.7 CuT
MUFFLER
9.5 CuT
7.9 CuT
HPS
MUFFLER
12.7 CuT
9.5 CuT
12.7 CuT
REFRIGERANT FLOW
COMPRESSOR
ACCUMULATOR
COOLING
12.7 CuT
DC FAN MOTOR
PROPELLER FAN
4-WAY
VALVE
DISCHARGE PIPE
THERMISTOR
GAS LINE
STOP VALVE
LIQUID LINE
STOP VALVE
FIELD PIPING
LIQUID (6.4 CuT)
FIELD PIPING
GAS (12.7 CuT)
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
HEAT EXCHANGER (CONDENSER)
THERMISTOR
MOTOR
OPERATED
VALVE
OUTDOOR TEMPERATURE
THERMISTOR
3D092777

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTK(X)M-P Series and is the answer not in the manual?

Daikin FTK(X)M-P Series Specifications

General IconGeneral
BrandDaikin
ModelFTK(X)M-P Series
CategoryHeat Pump
LanguageEnglish

Related product manuals